Upgrade instructions¶
- Install the ST-LINK driver LINK
- Extract the latest version of the ST-LINK/V2-1 firmware LINK
- Run the STLinkUpgrade.exe program
- Press Connect
- If you installed the ST-LINK driver correctly above, you should see your device details
- Press 'Yes'
- You should now have successfully upgraded the firmware. If you encounter problems, please ask here.
Revision history¶
V2.J23.M6¶
- Fixed the virtual comm port against a possible delay in data reception by the host (like a cache flush issue)
- Fixed the virtual comm port against a possible communication failure during data emission by the host on some USB3 ports
- Fixed the mass storage interface enumeration after a programming of the target application, reducing the risk to loose the VCP communication during such operation
- Fixed the suppression of one target reset sequence during the power on sequence
- Changed the SWD communication in order to reduce the noise generated by SWD signals
V2.J22.M5¶
- ST-Link firmware upgrade for correct support of Nucleo-F411RE by the MSD interface (drag&drop functionality).
V2.J21.M5¶
- This version contains a fix against a regression in TNRST management that does not directly impact the mbed drag&drop programming, but when the board is used from a debugger.
V2.J20.M4¶
- Suppressed “high speed device” notification when plugging to a non-high speed USB port or to an USB3 port
- Keep the virtual com port session valid (if any opened), when reprogramming the application
- Fixed potential lockup condition in SWV trace management and Virtual Com Port management
V2.J19.M3¶
- Fixes 8.3 filename error
- Fixes Chrome browser support